Productdetails
Nominale spanning 220-240 V wisselstroom, 50 Hz/60 Hz Stand-by-vermogen ≤0,5W
Laadvermogen 400W (inductief); 800W (resistief) Montagehoogte 2,5-6m
Bedrijfstemperatuur -25°C... +60°C Levensduur 5 jaar garantie @Ta 230V vollast
Markeren

anti-interference motion sensor with dip switch

,

trip-proof light sensor remote configuration

,

on off function motion sensor

Laat een bericht achter
Productomschrijving
Anti-interference Trip-proof Light ON/OFF Motion Sensor
Features
  • Low Impedance sensor antenna patent helps anti-interference kinds of wireless signal like 5G, Wi-Fi, Bluetooth etc.
  • Patented dipole antenna design brings reliable detecting, avoid false trigger when sensor built-in backside of metal LED plate.
  • Comply with RED approval.
  • Non-isolated switching power supply, will not affect the PF value of the whole lamp, in accordance with the latest ERP.
  • Adjustable detecting sensitivity via DIP switches, suitable to variety of installation sites.
  • Ultra-slim design for Tri-proof LED light
  • Support 6m Max. Mounting height
  • Dialing code and remote control are both supported for parameters setting.
  • 5 years warranty
Technical Parameters
Input Operating Voltage Range 120-277V AC 50Hz/60Hz
Rated Voltage 220-240V AC, 50Hz/60Hz
Stand-by Power ≤0.5W
Surge Test L--N: 1kV
Output Working Mode ON/OFF function
Type of Load Inductive or Resistive
Load Capacity 400W (Inductive); 800W (Resistive)
Max. Surge Capacity 10A relay; 30A (50% Ipeak, twidth =500uS, 230Vac full load, cold start)
Sensor Parameters Operating Frequency 5.8 GHz ±75 MHz, ISM Band
Transmitting power 0.5mW Max.
Hold time 5S/30S/90S/5Min (by two dialing codes)
10S/90S/3Min/10min (by remote MH03)
Detection Sensitivity 100%/75%/50%/25% (by two dialing codes)
100%/50% (by remote MH03)
Daylight Sensor 25lux/Disable (by one dialing code)
5lux/15lux/50lux/Disable (by remote MH03)
Detecting Radius >3m (mounting height 3-4m); >2m (mounting height 6m)
Mounting Height 2.5-6m, and 4m is of the max. detecting radius
Detecting Angle 150° (Wall mounted)
Operating Environment Operating Temperature -25℃…+60℃
Storage Temperature -40℃…+80℃ (Humidity: 10%-95% Non-condensing)
Certificate Standards Safety standards EN61058-1
EMC standards EN300440; EN301489-1; EN55015; EN61547; EN61000-3-2; EN61000-3-3; EN62479
Environmental Requirement Compliant to RoHS
Certificate CE, RED
Others Wiring Press-in Type Terminals, wire diameter: 0.75-1.5mm²
IP Rating IP20
Protection Class Class II
Installation Built-in
Dimension 77.5*34.5*22mm
Package Bubble bag+Clapboard + Carton(K=A)
Net Weight 45±3g
Lifetime 5 years warranty @Ta 230V full load
Note: 1. "N/A" means not available. 2. Detection area is affected by volume of motion object and motion speed. The detection area is tested by a 165cm height person and walking speed is 1m/s.
Function
On/OFF Function
Anti-interference Trip-proof Light ON/OFF Motion Sensor, Support Front Dip Switch And Remote Configuration 0
*The sensor is designed for connect one load only. Connect more than one loads may damage the sensor.
Structure
Anti-interference Trip-proof Light ON/OFF Motion Sensor, Support Front Dip Switch And Remote Configuration 1
Remote Control (MH03)
DIP Switch Setting
Detection Area
Setting Switch 1 Switch 2
100% ON ON
75% - ON
50% ON -
25% - -
Hold Time
Setting Switch 3 Switch 4 Time
ON ON 5S
- ON 30S
ON - 90S
- - 5min
Daylight Sensor
Setting Switch 5 Light Level
ON 25Lux
- Disable
*"Disable" means the daylight sensor not work. It will turn on light once motion is detected regardless of ambient light.
Override Function

Power off, quick switch ON/OFF sensor 3 times (ON-OFF-ON-OFF-ON) within 2sec to override sensor function. Lights will blink 3 times and then switch ON all the time. Power off and on again to recover sensor function.

Initialization

After power on, the sensor automatically turns on light at 100% brightness. After 10sec, it turns off the light. During the initialization, the sensor is not able to detect movement.

Factory Setting

Detection area: 100%, Hold Time: 5S, Daylight Sensor: Disable

Application Notice
  • The sensor should be installed by a professional electrician. Please turn off the power before installing, wiring, changing the setting of the DIP switch.
  • The sensor which installed in the plastic and glass lampshade will reduce the sensitivity. For every 3mm increase in thickness, the sensitivity will be reduced by 20%.
  • The light sensitivity threshold is in a sunny environment, no shadow and ambient light diffuse reflection. Ambient lux level will be different in different environment, weather, climate, time-of-day and season.
  • The parameters of the sensor may need to be reconfigured in different installation environments.
  • This sensor is for indoor use only. It will affect the waterproof effect for outdoor use. Wind, rain, and moving objects around will cause false triggering.
  • The distance between any inductive sensors should be greater than 3m.
  • Do not place the sensor close to high-density objects such as metal, glass, concrete walls, etc, false triggering could happen. When the sensor is installed in a metal lamp, metal reflective surface, or a narrow enclosed environment, the microwave will be reflected repeatedly and cause false triggering. Please reduce the sensitivity or contact the manufacturer for technical support.
  • Please ensure that there are no moving signals around the sensor, such as fan, DC motor, sewer pipe, air outlet, etc., the sensor may generate false trigger.
  • You are advised to test 5 samples before mass application of sensor in a new lighting project.
  • Due to continuous improvement, the contents of this instruction could be changed without prior notice.
  • If the sensor is built under metal board, make sure the sensor surface should to be seamless close to the metal plate without space.